Toxicology Report

Science-backed PDE/ADE, OEL & OEB derivation by certified toxicologists with ex-agency experts -

Tasimelteon

What is Tasimelteon?

CAS No: 609799-22-6

Tasimelteon is a selective dual melatonin receptor agonist indicated for the treatment of Non-24-Hour Sleep-Wake Disorder (N24HSWD). Occurring commonly in blind individuals without light perception, this condition is often characterized by periods of night-time insomnia and day-time sleepiness. In blind individuals, a lack of light stimulation causes an extension of the 24-hour circadian cycle and can lead to progressively delayed sleep onset. By activating melatonin receptors MT1 and MT2 in the suprachiasmatic nucleus of the brain, tasimelteon has been shown to improve sleep by resynchronizing the circadian rhythm through its “non-photic” mechanism. Tasimelteon is currently the only drug available for the treatment of N24HSWD and was granted orphan drug status by the FDA in 2010.

To derive PDE/ADE, OEL, and OEB values, Masuu Global follows a scientifically justified, risk-based toxicological assessment approach in accordance with internationally recognized guidelines and industry best practices that are widely accepted by regulatory authorities, including European Medicines Agency (EMA), Pharmaceutical Inspection Co-operation Scheme (PIC/S), and Agência Nacional de Vigilância Sanitária (ANVISA).

Request Your Assessment

Add this compound to your inquiry list and our team will follow up with full documentation, pricing, and licensing terms.

View Inquiry List →
What's included:
Full OEL derivation · ADE/PDE value · Control band assignment · All cited references · EMA / ICH Q9 compliance
9,000+
Toxicological & Exposure
Assessment Reports Delivered
70+
Subject Matter Experts
across global operations
12
In-House Ex-Agency
Toxicologists
3
Certification Bodies:
ERT · UKRT · DABT

Assessment Methodology

Masuu Global follows a scientifically justified, risk-based toxicological approach aligned with internationally recognized guidelines accepted by EMA, PIC/S, and ANVISA.

EMA – Guideline on Setting Health-Based Exposure Limits (HBELs)

Provides the framework for establishing scientifically justified PDE/ADE values for use in shared manufacturing facilities.

PIC/S – Shared Facilities and Contamination Control Guidance

Supports the application of HBEL-based approaches for cross-contamination prevention and cleaning validation.

ICH Q9 – Quality Risk Management

Provides a structured methodology for risk identification, assessment, control, communication, and review.

ICH M7 – Assessment and Control of DNA-Reactive (Mutagenic) Impurities (where applicable)

Applied for compounds with potential mutagenic or genotoxic concerns.

Risk-Based Toxicological Assessment

Comprehensive evaluation of available toxicological and pharmacological data, including NOAEL, LOAEL, BMDL, pharmacological potency, carcinogenicity, reproductive and developmental toxicity, sensitization potential, and target organ toxicity.

Weight-of-Evidence (WoE) Approach

Integration and critical review of all relevant data sources, including non-clinical studies, clinical studies, human exposure data, pharmacological information, post-marketing safety data, and structure–activity relationship (SAR/QSAR) assessments.

Report Preparation Process

Every assessment moves through a rigorous five-stage workflow — from data gathering to regulatory-ready delivery.

01

Comprehensive Data Review

Assessment of pharmacology, toxicology, clinical data, literature, and available regulatory information.

02

Scientific Evaluation

Identification of critical endpoints and selection of appropriate exposure limits.

03

PDE / HBEL Derivation

Transparent and scientifically justified calculations aligned with global toxicological principles.

04

Ex-Agency Expert Review (Our Differentiator)

Reports are reviewed with an ex-agency perspective, bringing regulatory expectations, inspection readiness, and practical implementation into every assessment.

05

Final Report Delivery

Regulatory-ready reports with scientific rationale, calculations, and clear recommendations by certified toxicologists (ERT, UKRT and DABT).

Why Masuu Global?

Our ex-agency toxicologists bring a practical regulatory perspective that transforms how assessments are built, reviewed, and defended.

✓

Regulatory expectation–driven assessments aligned with how authorities actually evaluate submissions.

✓

Inspection-ready reports — scientifically defensible and audit-prepared from day one.

✓

Faster review cycles with direct decision support from certified toxicologists (ERT, UKRT, DABT).

✓

Practical implementation recommendations that translate science into actionable contamination control.

✓

Reduced internal effort — offload complex assessments without sacrificing quality or defensibility.

✓

Global reach across PDE/ADE, HBEL, OEL, OEB, cleaning validation, and impurity assessments.

Ready to request your assessment?

Add this compound to your inquiry list, or browse our full database of 3,000+ molecules.

Frequently Asked Questions

Tasimelteon is a chemical substance that may be handled in pharmaceutical and chemical manufacturing. The precise toxicological profile and occupational exposure considerations should be established from reliable substance-specific evidence rather than inferred from the name alone. Reviewing the available data and intended handling conditions can support a documented assessment of worker protection and potential cross-contamination risk.

A PDE or ADE sets a health-based limit on daily exposure to Tasimelteon from residual carryover. Manufacturers use it in cross-contamination risk assessments and cleaning validation when the compound is processed in shared equipment or facilities. Whether a report is required depends on how it is used and on applicable regulatory expectations.

When published toxicity data for Tasimelteon are limited, the assessment may use a structured, risk-based evaluation of the evidence that is available. Depending on the substance, this can include relevant information on related compounds, structure-based assessment, and documented assumptions. The report should clearly identify data gaps and explain how they affect confidence in the conclusion. ICH M7 principles may apply where relevant to mutagenic impurities.

Where Tasimelteon is a medicinal substance and suitable therapeutic-dose information is available, that information may provide context for the assessment but should not automatically determine a PDE or OEL. The assessor must consider the relevant toxicological endpoint, route, population, data quality, and intended exposure scenario. Any use of pharmacological or clinical information should be scientifically justified and documented alongside the other relevant evidence.

A PDE for Tasimelteon is established for a defined assessment scope and exposure route, and it should not automatically be treated as applicable to every route. A value derived for oral exposure may not directly represent inhalation or dermal risk. Any route-to-route extrapolation requires scientific justification, and the report should state the route, assumptions, limitations, and intended use of the value.

An OEL is derived by reviewing the toxicological and occupational health evidence, identifying the critical effect, and applying a recognized assessment methodology. The final value should come with a documented rationale, clearly stated units, and the exposure duration it applies to, so it can be used confidently in workplace risk assessment.

An OEB places Tasimelteon in a hazard category using a defined banding framework and the available toxicological evidence. Criteria and numerical ranges differ between frameworks, so the report should identify the system used. The band then guides the level of containment and handling controls suited to the compound.

The assessment for Tasimelteon should be reconsidered when material new toxicological information becomes available, the substance’s use or exposure circumstances change, or relevant regulatory guidance is updated. A review may also be appropriate if the manufacturing process, route of exposure, or risk-management assumptions change. Documenting the reason for review and the evidence considered helps maintain a transparent and current risk assessment.

Uncertainty factors in an assessment of Tasimelteon account for matters such as differences between test species and humans, variability among people, study duration, study quality, and gaps in the evidence. The factors should be selected individually and justified scientifically rather than applied automatically. The report should show how the factors influence the final health-based limit and identify key assumptions.

A report for Tasimelteon should describe the assessment scope, the evidence reviewed, the scientific rationale, relevant calculations, uncertainty factors where applicable, assumptions, and the resulting conclusions or recommendations. It should identify important data gaps and explain how they affect interpretation. The content should be tailored to the substance and intended use, with clear documentation that allows technical reviewers to follow the reasoning.

Masuu Global follows a scientifically justified, risk-based approach aligned with internationally recognized guidance accepted by regulators, including the EMA guideline on health-based exposure limits, PIC/S guidance on shared facilities and contamination control, ICH Q9 quality risk management, and ICH M7 where applicable.

Use the Request Your Assessment option on this page and add Tasimelteon to your inquiry list. The Masuu Global team will follow up with full documentation, pricing, and licensing terms. Mention your intended use and market so the scope of the report can be confirmed.

Book a Demo