Toxicology Report

Science-backed PDE/ADE, OEL & OEB derivation by certified toxicologists with ex-agency experts -

Febuxostat

What is Febuxostat?

CAS No: 144060-53-7

Febuxostat is a non-purine xanthine oxidase (XO) inhibitor. In early 2008, febuxostat was granted marketing authorization by the European Commission for the treatment of chronic hyperuricemia and gout. In the following year, the FDA for approved febuxostat for use in the chronic management of hyperuricemia in adult patients with gout who have an inadequate response or intolerance to [allopurinol]. Gout is a form of arthritis that is caused by the accumulation of uric acid crystal in or around a joint, leading to inflammation and further deposition of uric acid crystal deposition in bones, joints, tissues, and other organs in the long term. Gout is closely associated with hyperuricemia. Febuxostat works by inhibiting the activity of an enzyme that is responsible for the synthesis of uric acid, thereby reducing serum uric acid levels. In February 2019, a black box warning for febuxostat was added, based on the findings of a post-market clinical study (the CARES trial) where there was an increased risk of cardiovascular (CV) fatal outcomes in patients with gout and known cardiovascular disease treated with febuxostat, when compared to those treated with allopurinol. The manufacturer and the FDA advise health professionals to limit the use of febuxostat to second-line therapy in patients who have inadequate response or intolerance to allopurinol, and to avoid the use of febuxostat in patients with cardiovascular diseases.

To derive PDE/ADE, OEL, and OEB values, Masuu Global follows a scientifically justified, risk-based toxicological assessment approach in accordance with internationally recognized guidelines and industry best practices that are widely accepted by regulatory authorities, including European Medicines Agency (EMA), Pharmaceutical Inspection Co-operation Scheme (PIC/S), and Agência Nacional de Vigilância Sanitária (ANVISA).

Request Your Assessment

Add this compound to your inquiry list and our team will follow up with full documentation, pricing, and licensing terms.

View Inquiry List →
What's included:
Full OEL derivation · ADE/PDE value · Control band assignment · All cited references · EMA / ICH Q9 compliance
9,000+
Toxicological & Exposure
Assessment Reports Delivered
70+
Subject Matter Experts
across global operations
12
In-House Ex-Agency
Toxicologists
3
Certification Bodies:
ERT · UKRT · DABT

Assessment Methodology

Masuu Global follows a scientifically justified, risk-based toxicological approach aligned with internationally recognized guidelines accepted by EMA, PIC/S, and ANVISA.

EMA – Guideline on Setting Health-Based Exposure Limits (HBELs)

Provides the framework for establishing scientifically justified PDE/ADE values for use in shared manufacturing facilities.

PIC/S – Shared Facilities and Contamination Control Guidance

Supports the application of HBEL-based approaches for cross-contamination prevention and cleaning validation.

ICH Q9 – Quality Risk Management

Provides a structured methodology for risk identification, assessment, control, communication, and review.

ICH M7 – Assessment and Control of DNA-Reactive (Mutagenic) Impurities (where applicable)

Applied for compounds with potential mutagenic or genotoxic concerns.

Risk-Based Toxicological Assessment

Comprehensive evaluation of available toxicological and pharmacological data, including NOAEL, LOAEL, BMDL, pharmacological potency, carcinogenicity, reproductive and developmental toxicity, sensitization potential, and target organ toxicity.

Weight-of-Evidence (WoE) Approach

Integration and critical review of all relevant data sources, including non-clinical studies, clinical studies, human exposure data, pharmacological information, post-marketing safety data, and structure–activity relationship (SAR/QSAR) assessments.

Report Preparation Process

Every assessment moves through a rigorous five-stage workflow — from data gathering to regulatory-ready delivery.

01

Comprehensive Data Review

Assessment of pharmacology, toxicology, clinical data, literature, and available regulatory information.

02

Scientific Evaluation

Identification of critical endpoints and selection of appropriate exposure limits.

03

PDE / HBEL Derivation

Transparent and scientifically justified calculations aligned with global toxicological principles.

04

Ex-Agency Expert Review (Our Differentiator)

Reports are reviewed with an ex-agency perspective, bringing regulatory expectations, inspection readiness, and practical implementation into every assessment.

05

Final Report Delivery

Regulatory-ready reports with scientific rationale, calculations, and clear recommendations by certified toxicologists (ERT, UKRT and DABT).

Why Masuu Global?

Our ex-agency toxicologists bring a practical regulatory perspective that transforms how assessments are built, reviewed, and defended.

Regulatory expectation–driven assessments aligned with how authorities actually evaluate submissions.

Inspection-ready reports — scientifically defensible and audit-prepared from day one.

Faster review cycles with direct decision support from certified toxicologists (ERT, UKRT, DABT).

Practical implementation recommendations that translate science into actionable contamination control.

Reduced internal effort — offload complex assessments without sacrificing quality or defensibility.

Global reach across PDE/ADE, HBEL, OEL, OEB, cleaning validation, and impurity assessments.

Ready to request your assessment?

Add this compound to your inquiry list, or browse our full database of 3,000+ molecules.

Book a Demo